This is a step-by-step guide to installing the Hex ezCAN Tagus on Triumph Tiger 1200 models.
IMPORTANT: This installation guide is only applicable to the Triumph motorcycle models listed below. If you are installing an ezCAN on a Triumph model that is not in the model list below, refer to the ezCAN for Triumph Installation Guides page for guidance.
This installation guide covers the following Tiger 1200 models manufactured from 2022 onward:
Note: As well as the items above, the ezCAN Tagus installation kit includes a Hex ezCAN universal splitter cable (below). This cable is for use on Tiger 850 and Tiger 900 models only. It is not applicable to the Tiger 1200.
Want to purchase an ezCAN from your local distributor? Click the button on the right.
Want to purchase an ezCAN directly? Click the button on the left.
This is a good time to:
Diagnostic connector types:
Depending on year model, two different diagnostic connector types are used on ezCAN Tagus-compatible Triumph Tiger 1200s:
The OBD-II diagnostic connector used on earlier models looks like this:
The Euro 5-type diagnostic connector used on later models looks like this:

Step 1: Locate the diagnostic connector
Note: The diagnostic connector may be obscured by part of the bike’s wiring harness. If you cannot see the connector, move the wiring harness portion indicated by the green arrow to access the connector.
IMPORTANT: Do not connect the ezCAN’s CAN-bus connector to any part of the motorcycle other than the diagnostic connector. If you do, the ezCAN will not function.
2. Remove the protective cap from the motorcycle’s diagnostic connector.
3. Depending on what diagnostic connector type the motorcycle has, connect the JWPF-to-OBD-II CAN-bus adaptor or the JWPF-to-Euro 5 CAN-bus adaptor to the ezCAN’s white JWPF connector.
4. Depending on what diagnostic connector type the motorcycle has, connect the ezCAN adaptor’s male OBD-II plug or male Euro 5 plug to the motorcycle’s diagnostic connector.
IMPORTANT: OBD-II connectors have no locking mechanism. If the bike has an OBD-II diagnostic connector, make sure the ezCAN adaptor’s male OBD-II plug cannot accidentally separate from the bike’s female OBD-II connector.
We recommend that you secure the join between the male and female OBD-II connectors with self-sealing tape or electrical insulation tape.
Route both ezCAN power supply cables from the main body location to the battery.
Ensure that all wiring is routed safely and securely, in a way that does not allow it to chafe or pinch. Where needed, secure all wiring to frame tubes or other components using the cable ties supplied with the ezCAN installation kit.
WARNING: For safety reasons, always disconnect the negative battery terminal first, and re-connect it last.
Note: The HEX ezCAN’s status LED should be solid green for approximately a minute after connection to the battery. After this time, the ezCAN enters Sleep Mode, and there will be no LED activity until the bike’s ignition is switched ON.
The ezCAN installation kit includes four two-wire stub connectors with male connection terminals, orange power wires and black ground wires.
The following parts are also included:
If the accessory to be connected to a power circuit has three wires, convert a two-wire stub connector to a three-wire connector as shown in the Connecting 3-wire LED lights section of the HEX ezCAN User Manual (downloadable from here).
If the accessory to be connected to a power circuit has two wires, seal the stub connector’s empty terminal cavity as shown in the Connecting 2-wire accessories section of the HEX ezCAN User Manual.
If any of the ezCAN’s power circuits will not be used, we recommend that you connect a blanking plug to the output plug of each unused circuit.
2-wire applications: insert a blanking seal.
3-wire applications: insert a PWM terminal wire.
Connect the male terminal of each stub connector to the relevant female ezCAN power circuit connector (below).
Connecting a 2-wire accessory to an ezCAN stub connector:
Connecting a 3-wire accessory to an ezCAN stub connector:
Connecting low-power smart accessories to a power circuit:
If you are installing ‘smart’ accessories (that is, low-power accessories capable of intelligent input and control through the ezCAN’s LIN bus), note the following:
Read the Hex ezBUS and Configuring Hex ezBUS functionality sections of the ezCAN user manual (downloadable from here) for detailed information on how to use ezBUS functionality.
Note that if the white circuit is set to ezBUS mode, its fuse trip limit is set to 15 Amps by default. If needed, ezBUS PWR functionality can be used to increase the white circuit’s current capacity to a maximum of 30 Amps in ezBUS mode. See the relevant section of the ezCAN User Manual for details.
IMPORTANT: If the accessory stub connectors included in your ezCAN installation kit do not have orange power wires, but instead have colours that match the colouring of the ezCAN power circuits (as seen below), always connect like-to-like (red stub connector to red power circuit, blue stub connector to blue power circuit, and so on.)
The HEX ezCAN Extension Kit contains everything you need to connect front auxiliary lights, rear accessory lights and a horn to the ezCAN. It also includes additional connectors that allow you to connect other accessories.
WARNING: Test and check your installations and accessories in a safe, controlled environment before first use. Caution is advised at all times. Extra vigilance is needed when testing new features or accessories. You do so at your own risk.
DISCLAIMER: Hex Innovate is not liable for any injury or damage, howsoever caused, and all products and services are used at your own risk.
Before finalizing the ezCAN installation, or re-installing any components you may have removed, it is important that you test all newly installed accessories for satisfactory fitment and correct operation.
Many ezCAN-powered accessories can be tested by switching the ignition ON and operating the relevant controls. Exceptions include:
Complete the ezCAN installation as follows: